Thermocouple Virtual Chart Recorder - iTCX-W

  • Virtual Chart Recorder
  • Two Thermocouple Channels
  • Web Server
  • 10 Popular T/C Types
  • Accurate
  • Email Alarms
  • Data Logging
  • iTCX-W Two K-Type Wire TC's Included
  • No Special Software Required

View Temperature from One or Two Thermocouples with a Web Browser

The iTCX transmitters can take Thermocouple Types J, K, T, E, R, S, B, C, N, and L measuring temperatures up to 1,820°C (3,308°F). The iTCX can display and chart absolute measurements in two locations and a differential measurement between the two locations.

Award-winning Technology
The iTCX is simple to install and use, and features award-winning iServer technology that requires no special software except a Web Browser. The iTCX connects to an Ethernet Network with a standard RJ45 connector and sends data in standard TCP/IP packets. It is easily configured with a simple menu using a Web Browser and can be password protected. From within an Ethernet LAN or over the Internet, the user simply types its IP address or an easy to remember name in any Web Browser, and the iTCX serves a Web Page with the current readings.

Email Alarms
The iTCX can send an email or text message reporting the status or an alarm condition over the Internet to any individual or distribution list.

 

Web Server Screen Shots

Screen Shot Engineering

Fig. 1- WEB page displaying data received from the Thermocouples

Screen Shot Engineering Configuration

Fig. 2- WEB page displaying the graph of the received data

Screen Shot Engineering Configuration

Fig. 3 - Device configuration through embedded WEB server

Thermocouple Chart
Input Type Range Accuracy
J Iron-Constantan -210 to 760°C / -346 to 1400°F 0.4°C / 0.7°F
K CHROMEGA®-ALOMEGA® -260 to -160°C / -160 to 1372°C
-436 to -256°F / -256 to 2502°F
1.0°C / 0.4°C
1.8°F / 0.7°F
T Copper-Constantan -270 to -190°C / -190 to 400°C
-454 to -310°F / -310 to 752°F
1.0°C / 0.4°C
1.8°F / 0.7°F
E CHROMEGA®-Constantan -270 to -220°C / -220 to 1000°C
-454 to -364°F / -364 to 1832°F
1.0°C / 0.4°C
1.8°F / 0.7°F
R Pt/13%Rh-Pt -50 to 40°C / 40 to 1768°C
-58 to 104°F / 104 to 3214°F
1.0°C / 0.5°C
1.8°F / 0.9°F
S Pt/10%Rh-Pt -50 to 100°C / 100 to 1768°C
-58 to 212°F / 212 to 3214°F
1.0°C / 0.5°C
1.8°F / 0.9°F
C 5%Re-W/26%Re-W 0 to 2320°C / 32 to 4208°F 0.4°C / 0.7°F
N Nicrosil-Nisil -250 to -100°C / -100 to 1300°C
-418 to -148°F / -148 to 2372°F
1.0°C / 0.4°C
1.8°F / 0.7°F
L J DIN -200 to 900°C / -328 to 1652°F 0.4°C / 0.7°F

Certifications

 

Part Number:

Part Number Price Description
 iTCX-W $340.00 iServer MicroServer™ for dual thermocouple input. The iTCX-W includes 2 type K thermocouples with 36” [1m] of 24 AWG PTFE insulated wire and a molded mini-connector with snap-on strain relief and universal (100-240 Vac) power adapter
 iTCX-D $340.00 DIN Rail iServer MicroServer™ for dual thermocouple input
 iTCX-W/N-CAL-3J $455.00 Available with NIST traceable calibration certificate. Three temperature points for each input (for new units)
 iTCX-D/N-CAL-3J $455.00 Available with NIST traceable calibration certificate. Three temperature points for each input (for new units)
 iTCX-W/N-CAL-3K $455.00 Available with NIST traceable calibration certificate. Three temperature points for each input (for new units)
 iTCX-D/N-CAL-3K $455.00 Available with NIST traceable calibration certificate. Three temperature points for each input (for new units)
 iTCX-W/N-CAL-3T $455.00 Available with NIST traceable calibration certificate. Three temperature points for each input (for new units)
 iTCX-D/N-CAL-3T $455.00 Available with NIST traceable calibration certificate. Three temperature points for each input (for new units)

 


As low as $340.00
Thermocouple Virtual Chart Recorder - iTCX-W is available to buy in increments of 1

Specifications

Thermocouple Input
Temperature Range: Refer to Thermocouple Chart Below
Temperature
Accuracy: Refer to Thermocouple Chart Below
Resolution:
/0.1°
Temperature Stability: 0.08°C/°C
Thermocouple Cold End Tracking:
0.05°C/°C

Thermocouple Lead Resistance:
100 ohm max.
Thermocouple Type (ITS 90): J, K, T, E, R, S, B, C, N, L


iServer Specifications
Interface:
Ethernet 10Base-T
Connector: RJ45
Supported Protocols: TCP/IP, UDP/IP, ARP, ICMP, DHCP, DNS, HTTP, Telnet
Indicators (LED’s): Power, Network Activity, Network Link and Diagnostics
Memory: 512 Kbyte Flash, 16 Kbyte SRAM
Management: Device configuration and monitoring through embedded Web server
Software Firmware upgradeable. Including an Excel program for automatic data logging within definable time intervals, compatible with all Windows operating systems.
Embedded Web Server: Serves Web pages containing real-time data and live updated charts within definable time intervals.
Operating Temperature: 0 to 70°C (32 to 158°F)
Storage Temperature: -40 to 125°C (-40 to 257°F)

 

Power
Power Input - iTCX-W: 9 - 12Vdc
Safety Qualified ac Power Adapter:
Nominal Output: 9 Vdc @ 500mA, included.
Input: 100 - 240Vac, 50/60Hz
Consumption: 2.5 W max.

Power

Universal ac Power Adapter
included with
iTCX-W

Power Input - iTCX-D: 10-32 Vdc
Switching Power Supply sold separately iDRN-PS-1000)
Consumption: 2.5 W max.

Power

iDRN-PS-1000 $150 for iTCX-D


Packaging

Material - iTCX-W:
Metal case with flange mount
Dimensions:
20.8H x 61.6W x 112.0D mm
(0.83 x 2.93 x 4.41 in)

Material - iTCX-D:
Polycarbonate case with DIN Rail mount
Dimensions:
90.2H x 25.1W x 115.0D mm
(3.54 x .99 x 4.53 in)
Weight: 113 g (0.25 lbs.)

Thermocouple Chart
Input Type Range Accuracy
J Iron-Constantan -210 to 760°C / -346 to 1400°F 0.4°C / 0.7°F
K CHROMEGA®-ALOMEGA® -260 to -160°C / -160 to 1372°C
-436 to -256°F / -256 to 2502°F
1.0°C / 0.4°C
1.8°F / 0.7°F
T Copper-Constantan -270 to -190°C / -190 to 400°C
-454 to -310°F / -310 to 752°F
1.0°C / 0.4°C
1.8°F / 0.7°F
E CHROMEGA®-Constantan -270 to -220°C / -220 to 1000°C
-454 to -364°F / -364 to 1832°F
1.0°C / 0.4°C
1.8°F / 0.7°F
R Pt/13%Rh-Pt -50 to 40°C / 40 to 1768°C
-58 to 104°F / 104 to 3214°F
1.0°C / 0.5°C
1.8°F / 0.9°F
S Pt/10%Rh-Pt -50 to 100°C / 100 to 1768°C
-58 to 212°F / 212 to 3214°F
1.0°C / 0.5°C
1.8°F / 0.9°F
C 5%Re-W/26%Re-W 0 to 2320°C / 32 to 4208°F 0.4°C / 0.7°F
N Nicrosil-Nisil -250 to -100°C / -100 to 1300°C
-418 to -148°F / -148 to 2372°F
1.0°C / 0.4°C
1.8°F / 0.7°F
L J DIN -200 to 900°C / -328 to 1652°F 0.4°C / 0.7°F
More Information
Part Number
No
Manufacturer
Newport Electronics
Write Your Own Review
You're reviewing:Thermocouple Virtual Chart Recorder - iTCX-W
Your Rating

  • 510 606-1012

    Round-the-clock free hotline (24/7)
  • Return & Exchange

    You can return or exchange the item within 14 days.
  • Satisfaction Guarantee

    We are committed to your satisfaction with every order.
To Top